Update¶
Hint - no Internet access
If the server on which you want to install SEAL Operator/SEAL Print Client does not have Internet access, use another server with Internet access for logging on to the SEAL Systems delivery platform and downloading the folder. Then, copy the downloaded zip file to the server on which you want to install SEAL Operator/SEAL Print Client.
Hint - configuration
The configuration in Consul etc. and the customer certificates set during the installation are not overwritten when updating.
Update To 1.3.0¶
Before the Update (1.3.0)¶
With SEAL Operator/SEAL Print Client 1.3.0, the MongoDB service has been replaced by a newer incompatible version. Therefore, the data stored in MongoDB has to be exported before the update and imported again after the update. For how to do this, refer to the SEAL-specific MongoDB documentation.
After the Update (1.3.0)¶
With SEAL Operator/SEAL Print Client 1.3.0, the MongoDB service has been replaced by a newer incompatible version. Therefore, the MongoDB data exported before updating has to be re-imported. For how to do this, refer to the SEAL-specific MongoDB documentation.
Update To 1.2.0¶
Before the Update (1.2.0)¶
With SEAL Operator/SEAL Print Client 1.2.0, the version of seal-consul-agent
was increased from 0.9.3 to 1.7.4, which has an incompatible database structure. Therefore, the data stored in Consul has to be exported before the update and imported again after the update.
-
Before updating SEAL Operator/SEAL Print Client, export the Consul data. For more information about exporting the data, refer to Administrate the System Configuration.
-
Remove all files from the
/opt/seal/data/seal-consul-agent
directory.
After the Update (1.2.0)¶
-
After the update, start
seal-consul-agent
, refer to Administrate Services. -
Import the data exported before the update, refer to Administrate the System Configuration.
Update SEAL Operator/SEAL Print Client¶
-
In a browser, log on to the SEAL Systems delivery platform with your logon data:
https://delivery.sealsystems.de
Hint - logon data
You receive the logon data from your Technical Project Manager at SEAL Systems.
-
Download the Operator - 1.3.1.258 - rpm folder. It is saved as
Operator - 1.3.1.258 - rpm.zip
. -
Extract
Operator - 1.3.1.258 - rpm.zip
. -
Switch to the
Operator - 1.3.1.258 - rpm
directory and start the installation of the packages contained there:cd "Operator - 1.3.1.258 - rpm"
sudo sh install.sh
Update the node-p4rest Service¶
The following steps are only required if the PLOSSYS netdome connector is used in your installation.
Execute the following steps on the server on which the PLOSSYS netdome system has been installed:
-
In a browser, log on to the SEAL Systems delivery platform with your logon data:
https://delivery.sealsystems.de
Hint - logon data
You receive the logon data from your Technical Project Manager at SEAL Systems.
-
Download the node-p4rest-5.3.2-405.x86_64.rpm file from the SEAL Systems delivery platform. It is saved as
node-p4rest-5.3.2-405.x86_64.rpm
. -
Install
node-p4rest-5.3.2-405.x86_64.rpm
.-
RHEL:
sudo yum install node-p4rest-5.3.2-405.x86_64.rpm
-
SUSE:
sudo zypper install node-p4rest-5.3.2-405.x86_64.rpm
-
Hint - configuration
The system variables set during the installation are not overwritten when updating.
After the Update (5.3.2)¶
After the update the following configuration entries need to be updated:
-
The configuration entry
ID_PROVIDER_CERT
has to be removed. -
The configuration entry
AUTH_ISSUER_URL
has to be added.
Manually Steps After Updating the SEAL Operator/SEAL Print Client Server to 1.3.0¶
With SEAL Operator/SEAL Print Client 1.3.0, the MongoDB service has been replaced by a newer incompatible version. Therefore, the MongoDB data exported before updating has to be re-imported. For how to do this, refer to the SEAL-specific MongoDB documentation.